Steven Engineering

Home | Log In / Register | Search | Order Pad | Request for Quote | Site Index | Contact Us

Corporate Products and Services Order Center Technical Support Customer Support
 

 
Schneider Electric > Drives and Soft Starts > E-Flex VFD
Schneider Electric
E-Flex VFD Configurator
Please use your Internet Explorer browser for full functionality
 

Part #:  
(If you already know the part number, paste it into the text
field above, then click here to describe and price the item.)
Press twice to confirm and clear form
 
*HP Rating:
*Enclosure Type:
*Voltage:
*Power Circuit:
*Control Options:
Light Cluster:
Communications:
Misc. Options:  X09 : 3% AC Line reactor (Replaces 3% DC Choke)
 A09 : 5% Line Reactor (Replaces 3% DC Choke)
 B09 : Line Contactor for 3-Contactor Bypass
 C09 : 3-15 PSI Transducer
 D09 : Omit Keypad
 E09 : Smoke Purge
 H09 : Add 2 Analog Outputs (1 is Standard)
 J09 : 0-10 VDC Speed Reference, No Charge
 K09 : cUL Listing Certification
 S09 : End Damper Control
 U09 : Seismic Qualifications

Click here for E-Flex Brochure
Click here for E-Flex User Manual
Click here for Altivar 61 Installation Man Low HP
Click here for E-Flex Specification Guide
Click here for E-Flex Spec Data
Click here for Altivar 61 Programming Guide
Click here for AC Drives Overview
Click here for SE Selector Quote Form
 
 
 
 

 

Distinguishing Characteristics
Enclosed VFD package with disconnect switch and optional bypass. 
Keypad with Full Text LCD customizable display. 
Many factory installed options are available. 
See full feature description at the bottom of this page. 

HP Code Enclosure Type Voltage Application
Type
Device Type
(Power Circuit)
Miscellaneous Options Enclosure Drawings
208 & 230V 460V W Y Mod X09 3% Line Reactor (relaces 3% DC Choke) Mod A09 5% Line Reactor (relaces 3% DC Choke) Mod B09 Line Contactor for 3-Contactor Bypass 208 & 230V 460V
Type 1 Type 12K Type 3R Type 1 Type 12K Type 3R 208V=2
230V=3
460V=4
Without Bypass Package Bypass Package NEMA 1
Type G
NEMA 12
Type A
NEMA 3R
Type H
NEMA 1
Type G
NEMA 12
Type A
NEMA 3R
Type H
208 & 230V 460V 208 & 230V 460V 208 & 230V 460V 208 & 230V 460V 208 & 230V 460V
Included  $155.00  $1,500.00  Included  $155.00  $1,500.00  1 hp  V=Variable Torque  $1,561.00  $1,530.00  $1,773.00  $1,739.00  $173.00  $173.00  $216.00  $216.00  $50.00  $50.00  8839-250-A  8839-250-A  8839-252-A  8839-250-A  8839-250-A  8839-252-A 
$155.00  $1,500.00  $155.00  $1,500.00  2 hp  $1,561.00  $1,653.00  $1,773.00  $1,878.00  $188.00  $188.00  $235.00  $235.00  $50.00  $50.00  8839-250-A  8839-250-A  8839-252-A  8839-250-A  8839-250-A  8839-252-A 
$155.00  $1,500.00  $155.00  $1,500.00  3 hp  $1,561.00  $1,791.00  $1,773.00  $2,036.00  $188.00  $188.00  $235.00  $235.00  $60.00  $50.00  8839-250-A  8839-250-A  8839-252-A  8839-250-A  8839-250-A  8839-252-A 
$155.00  $1,500.00  $155.00  $1,500.00  5 hp  $1,766.00  $1,928.00  $2,007.00  $2,191.00  $202.00  $202.00  $253.00  $253.00  $70.00  $50.00  8839-250-A  8839-250-A  8839-252-A  8839-250-A  8839-250-A  8839-252-A 
$155.00  $1,700.00  $155.00  $1,500.00  7.5 hp  $1,887.00  $2,044.00  $2,144.00  $2,323.00  $238.00  $238.00  $298.00  $298.00  $70.00  $60.00  8839-250-B  8839-250-B  8839-252-B  8839-250-A  8839-250-A  8839-252-A 
$155.00  $1,700.00  $155.00  $1,700.00  10 hp  $2,183.00  $2,226.00  $2,480.00  $2,578.00  $306.00  $306.00  $382.00  $382.00  $90.00  $70.00  8839-250-B  8839-250-B  8839-252-B  8839-250-B  8839-250-B  8839-252-B 
$362.00  $2,625.00  $155.00  $1,700.00  15 hp  $2,838.00  $2,479.00  $3,225.00  $2,817.00  $315.00  $315.00  $394.00  $394.00  $120.00  $78.00  8839-251-A  8839-251-A  8839-253-A  8839-250-B  8839-250-B  8839-252-B 
$362.00  $2,625.00  $155.00  $1,700.00  20 hp  $3,621.00  $2,892.00  $4,115.00  $3,286.00  $382.00  $382.00  $478.00  $478.00  $168.00  $90.00  8839-251-A  8839-251-A  8839-253-A  8839-250-B  8839-250-B  8839-252-B 
$362.00  $2,625.00  $155.00  $1,700.00  25 hp  $3,694.00  $3,083.00  $4,198.00  $3,503.00  $382.00  $382.00  $478.00  $478.00  $195.00  $120.00  8839-251-A  8839-251-A  8839-253-A  8839-250-B  8839-250-B  8839-252-B 
$362.00  $3,750.00  $362.00  $2,625.00  30 hp  $4,635.00  $3,686.00  $5,267.00  $4,189.00  $398.00  $398.00  $497.00  $497.00  $195.00  $120.00  8839-251-B  8839-251-B  8839-253-B  8839-251-A  8839-251-A  8839-253-A 
$362.00  $3,750.00  $362.00  $2,625.00  40 hp  $5,850.00  $4,424.00  $6,647.00  $4,800.00  $448.00  $448.00  $560.00  $560.00  $252.00  $168.00  8839-251-B  8839-251-B  8839-253-B  8839-251-A  8839-251-A  8839-253-A 
$362.00  $3,750.00  $516.00  $2,625.00  50 hp  $7,316.00  $5,222.00  $8,314.00  $5,934.00  $583.00  $583.00  $729.00  $729.00  $364.00  $195.00  8839-251-B  8839-251-B  8839-253-B  8839-251-A  8839-251-A  8839-253-A 
…  …  $516.00  $3,750.00  60 hp  …  $6,604.00  …  $7,505.00  …  $583.00  …  $729.00  …  $195.00  N/A  N/A  N/A  8839-251-B  8839-251-B  8839-253-B 
…  …  $516.00  $3,750.00  75 hp  …  $7,372.00  …  $8,378.00  …  $649.00  …  $811.00  …  $252.00  N/A  N/A  N/A  8839-251-B  8839-251-B  8839-253-B 
…  …  $516.00  $3,750.00  100 hp  …  $8,908.00  …  $10,122.00  …  $777.00  …  $971.00  …  $364.00  N/A  N/A  N/A  8839-251-B  8839-251-B  8839-253-B 

Control Option 208 & 230V 460V
A07 (6) (14)  Hand/Off/Auto, Speed Pot.  Included  Included 
B07 (6)  Hand/Off/Auto, Start/Stop, Speed Pot.  $100.00  $100.00 
C07 (1)  Start/Stop, Speed Pot.  $75.00  $75.00 
D07 (6) (8)  Hand/Off/Comm, Speed Pot.  $0.00  $0.00 
E07 (6) (8)  Hand/Off/Comm, Start/Stop, Speed Pot.  $100.00  $100.00 
N07  None  -$100.00  -$100.00 
Light Option 208 & 230V 460V
A08 (2) (15)  On/Run/Fault/Auto Lights  $80.00  $80.00 
B08 (2) (3)  On/Run/Fault/Bypass Lights  $80.00  $80.00 
C08 (2)  On/Run/Fault Lights  $65.00  $65.00 
Miscellaneous Options 208 & 230V 460V
X09  3% AC Line Reactor (Replaces 3% DC Choke)  See Above  See Above 
A09  5% AC Line Reactor (Replaces 3% DC Choke)  See Above  See Above 
B09 (4) (17)  Line Contactor for 3 Contactor Bypass  See Above  See Above 
C09 (9)  3-15 PSI Transducer  $180.00  $180.00 
D09 (12)  Omit Keypad  -$40.00  -$40.00 
E09 (5)  Smoke Purge  $80.00  $80.00 
F09 (13)  PROFIBUS DP  $400.00  $400.00 
H09 (10)  Add 2 Analog Outputs (1 is Standard)  $150.00  $150.00 
J09 (11)  0-10 Vdc Speed Reference, No Charge  $0.00  $0.00 
K09  cUL Listing Certification  $140.00  $140.00 
L09 (13)  LONWORKS Card  $400.00  $400.00 
M09 (13)  Modbus/Unitelway Card  $165.00  $165.00 
O09 (13)  Apogee P1 Card  $165.00  $165.00 
P09 (13)  METASYS N2 Card  $165.00  $165.00 
Q09 (13)  Ethernet TCP/IP Card  $165.00  $165.00 
R09 (13)  BACnet MSTP Card  $165.00  $165.00 
S09 (16)  End Damper Control  $115.00  $115.00 
U09  Seismic Qualifications  $215.00  $215.00 

Wiring Diagrams
Mod # Control Type W/Out Bypass (W) With Bypass (Y)
A07  Hand/Off/Auto, Speed Pot.  8839-075-1  8839-072-1 
B07  Hand/Off/Auto, Start/Stop, Speed Pot.  8839-073-1  8839-071-1 
C07  Start/Stop, Speed Pot.  8839-074-1  N/A 
E07  Hand/Off/Comm, Start/Stop, Speed Pot.  8839-079-1  8839-078-1 

Notes
(1) Control Option C07 is not compatible w/ Power Circuit Y (Bypass) or Light Cluster A08 or B08. 
(2) Light Cluster Option A08, B08, C08 cannot be selected together. Select only one. 
(3) Light Cluster Option B08 is not compatible w/ Power Circuit W (Without Bypass). 
(4) Line Contactor B09 is not compatible w/ Power Circuit W (Without Bypass). 
(5) Smoke Purge E09 Option (Fireman's Override) permits the motor to run at full speed. 
(6) Hand-Off-Auto Switch must be placed in the OFF position for AFC fault reset. 
(7) When Power Circuit Y Bypass is selected, AFC-Off-Bypass Switch and Test-Normal Switch is supplied. 
(8) When Communication Options are selected, Control Option D07 or E07 must be selected for control. A07 or B07 may be used for monitoring only. 
(9) C09 Option (3-15 PSI Transducer) is not compatible w/ Control Option C07, D07, or E07 as well as J09 0-10V Auto Speed Reference, H09 I/O Extension Card, F09, L09 M09, O09, P09, Q09 or R09 Serial Communication Cards. 
(10) H09 Option (I/O Extension Card) is not compatible w/ C09 3-15 PSI Transducer or Serial Comm Card F09, L09, M09, O09, P09, Q09 or R09. 
(11) J09 Option (Input Programmed for 0-10 VDC) is not compatible with Control Options C07, D07 or E07 or Misc. Option C09 (3-15 PSI Transducer.) 
(12) D09 Option (Omit Keypad from Door Enclosure) will require user to purchase a separate device to program the controller. 
(13) Serial Comm Options F09, L09, M09, O09, P09 Q09 and R09 cannot be selected together. Select only one. Serial Comm cannot be selected w/ H09 I/O Extension Card. Control Option D07 or E07 must be selected for monitoring and control with Serial Comm Opt. 
(14) Whenever keypad speed potentiometer is included, a separate speed potentiometer on door is not supplied. When Type 3R Enclosure or Option D09 (Omit Keypad) is selected, speed potentiometer is mounted on the enclosure door. 
(15) Light Option A08 is compatible with Control Options A07, B07, D07 and E07. 
(16) Option S09 (End Damper Control) is not compatible with Control Options D07 Hand-Off-Comm, Speed Pot or E07 Hand-Off-Comm, Start-Stop, Speed Pot. 
(17) Line Contactor B09 Option is not compatible with Type 3R Enclosure. 

Standard and Optional Features
Standard Features: 
• Altivar 61 VFD 
• Circuit Breaker Disconnect, Thru Door, Pad Lockable 
• AC Line fuses NOT required 
• 3% DC Buss Choke (Reactor) 
• NEMA Type 1 Enclosure 
• Keypad with Full Text LCD customizable display 
• Fused control power transformer 
• Industrial operator devices 
• HOA switch and speed pot 
• UL508C Listed and Coordinated with NEMA ICS 7.1 
• NEC 2005 Article 409 compliant 
• 100kA short circuit current rating on VFD & optional Bypass 
• Pre-programmed for typical HVAC applications 
• Top & Bottom conduit knock-outs 
• Integrated Modbus RS-485 port, RTU, Multidrop 
• Fire/Safety interlock in VFD & optional Bypass mode 
• Form C Run & Fault Contacts 
• Meets I/O requirements for typical HVAC applications 
Optional Features 
• LonWorks, BACnet MSTP, Metasys N2, Apogee P1, Ethernet or Profibus 
• NEMA Type 12K or 3R Enclosure 
• 3% AC Line Reactor (Replaces 3% DC Bus Choke that is included as standard) 
• 5% AC Line Reactor (Replaces 3% DC Bus Choke that is included as standard) 
• Full voltage bypass 
• Test/Normal selector switch 
• Line Contactor (for 3-Contactor Bypass requirements) 
• Pilot lights for power on, fault, run and bypass or auto mode 
• Smoke purge (Fireman’s override) 
• cUL Listing certification 
• End Damper Control 
• Seismic qualification 
• PowerSuite programming software & Cable kit (See Altivar 61 options) 

   

 
      Corporate Information | Products and Services | Order Center | Technical Support | Customer Support
© 2021 Steven Engineering, Inc. All Rights Reserved
230 Ryan Way · South San Francisco · California · 94080-6308
Toll Free Phone: (800) 258-9200 · Toll Free Fax: (888) 258-9200
Steven Engineering BlogSteven Engineering Twitter FeedSteven Engineering YouTube ChannelSteven Engineering LinkedIn Page